Polish manufacturer of radio devices since 1999Technical support+48 32 326 30 70
Example configurationCare and health

The therapist calls for support without leaving the patient

One 433.92 MHz system for the therapy rooms and the accessible toilet: a button by the treatment couch, a foot button under it, a toilet kit and a receiver at reception that shows the number of the calling point.

  • 8therapy rooms
  • 18transmitters out of 99 memory slots
  • 1receiver at reception
The therapist calls for support without leaving the patient
Illustrative image

01 / Investment context

What problem does this configuration solve?

The rehabilitation centre has eight therapy rooms, a toilet for people with disabilities and a reception desk at the entrance. A therapist usually works with a patient alone, and during standing exercises, gait training or a transfer from wheelchair to couch often supports them with both hands.

When a patient feels faint, slumps or falls, the therapist needs a second person — and cannot leave the room to look for one, or let go of the patient to reach for a phone. Shouting through a closed door unsettles patients in the waiting room and does not say where to go. The centre also needs a call for help from the accessible toilet and does not want to run two separate systems for this.

The investor’s goal: A call from any therapy room — by hand or by foot — and from the toilet reaches one receiver at reception, which shows where it came from.

How does this configuration work?

The toilet is covered by a toilet kit (TdN-01): a button with cancel key (PNH-201C), a pull-cord transmitter with cancel key (PNH-201SC), a signal unit above the door and an identification receiver (IDO-04/99). The toilet transmitters repeat the call every 30 seconds until someone cancels it on the spot. The kit’s receiver stands at reception and serves the whole system: the buttons from the therapy rooms are programmed into its memory too.

In each therapy room there is a call button in a wall frame by the couch (SPR-PK1/A/BAT) and a foot button under the couch (SPR-PN1) — for the moment when both hands are busy with the patient. The receiver shows the number assigned to the transmitter, and a list next to it assigns each number to a therapy room or the toilet. The receiver’s relay switches on a signal unit with adjustable volume at reception (SWR-108), set so that staff hear it without unsettling patients in the waiting room.

The receiver, the signal unit at reception and the signal unit above the toilet door run on 12 V DC from the system’s power supplies (SPR-ZS1). The person who goes to the therapy rooms to help can carry a pager (OBI-4SH) in which each therapy room and the toilet are separate zones — the call, with the zone number, then reaches them without going through reception.

02 / Operating principle

From signal to action.

One receiver at reception takes calls from eight therapy rooms and the accessible toilet and shows where they came from.

  1. 01 / Signal source

    Buttons By the couch and under it

    The therapist calls by hand or foot without letting go of the patient.

  2. 02 / Reception

    IDO-04/99 Receiver at reception

    Shows the number assigned to the transmitter that called.

  3. 03 / Notification

    SWR-108 Signal unit at reception

    Switched by the receiver’s relay, at a volume set for the waiting room.

Reception knows where to send the second person. A list next to the receiver assigns each number to a therapy room or the toilet; the person giving support can also carry a pager.

A simplified functional diagram.

03 / Installation components

Devices in this configuration

An example selection — the number of devices depends on the site.

TdN-01 — Toilet kit with IDO-04/99 receiver

TdN-01

Accessible-toilet kit: a button and a pull-cord transmitter with cancel key, a signal unit above the door and an identification receiver, which serves the whole system at reception.

Quantity: 1

IDO-04/99 — Identification receiver, 99 transmitters

IDO-04/99

The kit’s identification receiver, at reception: stores all 18 transmitters, shows the number of the one calling and switches on the signal unit through its relay.

Quantity: included in TdN-01

PNH-201C — Sealed button with cancel

PNH-201C

Button in the toilet: the call repeats every 30 seconds until someone cancels it on the spot with the cancel key.

Quantity: included in TdN-01

PNH-201SC — Pull-cord transmitter with cancel

PNH-201SC

Pull-cord transmitter in the toilet with a 2 m chain: the call repeats every 30 seconds until it is cancelled on the spot.

Quantity: included in TdN-01

SPR-PN1 — Foot button

SPR-PN1

Foot button under the couch: a call by foot when both hands are supporting the patient. Powered by a 3.6 V lithium cell.

Quantity: 8

SWR-108 — Signal unit with volume control

SWR-108

Light-and-sound signal unit at reception, switched by the receiver’s relay. A volume knob lets the sound be matched to the waiting room.

Quantity: 1

SPR-ZS1 — System power supply

SPR-ZS1

Mains power supply, 230 V AC: one at reception for the receiver and signal unit, the other by the toilet door for the signal unit above the entrance.

Quantity: 2

OBI-4SH

OBI-4SH

Pager for the person who gives support in the therapy rooms: the call, with the zone number of the room or toilet, reaches them directly. Charged by USB or wirelessly (Qi).

Quantity: optional

Catalogue figures describe a device under stated conditions, usually in open terrain, and are not a guaranteed range in every installation. Device quantities in the examples are indicative.

04 / Value for the investor

What does this solution give you?

Hands stay with the patient

The foot button calls for help at the moment when the therapist is holding the patient and cannot reach either the wall or a phone.

Reception knows where to send help

The number on the display points to a therapy room or the toilet, so the second person goes straight to the right place without knocking on door after door.

One system, room to grow

The toilet and eight therapy rooms use 18 transmitters against a receiver memory of 99 — further rooms are added to the same receiver.

05 / Before installation

What needs to be settled for a similar investment?

Before devices are chosen, what matters is the site’s conditions and how the system ties into the final installation.

Requirements to verify

  • The kit’s receiver shows numbers — a list of room numbers hangs at reception. If reception is to see names, a receiver with text labels is needed.
  • The volume and position of the signal unit at reception — so that staff always hear it and patients in the waiting room are not unsettled.
  • 230 V power at reception and by the toilet door for the power supplies of the receiver and signal units.
  • A range test from the therapy rooms farthest from reception, especially if they are on another floor.
  • Who is the “second person” who goes to help on each shift, and whether they should carry a pager.

Example configuration — it needs a technical selection for your site.

More from this sector

Care and health

A project for your site

Choose a nurse call system for your facility.

Send us the key requirements — GORKE will help define the scope, the technology and the components that fit the investment.

← Back to all solutions